Threaded ends disc check valve from AISI316 (CF8M) DN15-50 PN40 ABRA-D12

Share the link with your colleagues:

Threaded ends disc check valve from AISI316 (CF8M) DN15-50 PN40 ABRA-D12

Check valve is not deigned and should not ever be used as shut-of valve. Lakage rate - rate B according ISO 5208, GOST54808 and GOST 9544 at pressure drop of 1,1 PN
Price-list and available stock rest

Threaded ends disc check valve ABRA-D12:

Threaded ends disc check valve from AISI316 (CF8M) DN15-50 PN40 ABRA-D12Threaded ends disc check valve from AISI316 (CF8M) DN15-50 PN40 ABRA-D12Threaded ends disc check valve from AISI316 (CF8M) DN15-50 PN40 ABRA-D12

Main fields of application - the valve is used as shut-off (on-off) in the following applications:

  • Any systems with the following working medias:
    • water including seawater, technical, potable, drinking, district heating water, distilled, purified e.t.c.
    • salt brines, salt liquors, saline solutions; salt solutions
    • water steam (up to 8 bar),
    • air, compressed air and neutral gases,
    • natural gas, Freons, cooling agents - gaseous
    • alcohols,  acetic acid (vinegar, ethanoic acid, spirit of verdigris, acetous acid), pure, mixes and solutions
    • antifreezes including water glycol mixtures,
    • ammonia (hydrogen nitride),
    • moderate aggressive acids
    • all bases and alkali liquors
    • light and heavy petroleum products
    • other medias corresponding to material properties
  • cold water supply
  • hot water supply
  • district heating with any standard heat carrier (including antifreezes and non-freezing solutions)
  • steam lines up to 200°C,
  • condensate loops and lines,
  • technical water supply,
  • neutral and noble gas pipelines including natural gas,
  • water treatment and water intake,
  • mineral and synthetic oils transportation e.t.c.

Outline drawing  of ABRA-D-12 thread ends disc check valve:

Outline drawing  of ABRA-D-12 thread ends disc check valve

Check Valves symbols for piping and instrumentation diagram (P&ID):

Check valve symbol. Arrow shows the flow direction

Angle check valve symbol. Arrow shows the flow direction

Variant1. Check valve symbol. Arrow shows the flow direction.
Just Informative. Angle check valve symbol. Arrow shows the flow direction.

Dimentions, technical characteristics, weight,  Kv and Cv and opening pressure  - check valve ABRA-D12 thredad ends. Dimentions in mm. Table.

DN 15 20 25 32 40 50
Thread: regular-duty parallel, BSP(P), G" 1/2" 3/4" 1" 1 1/4" 1 1/2" 2"
PN
40 bar (4,0 MPa)
Temperature range °C:
Maximum short time temperature: 200 °C,
Minimal ambient temperature: - 60 °C,
Gode ABRA-
-D12-H12W-
-1000-015
ABRA-
-D12-H12W-
-1000-020
ABRA-
-D12-H12W-
-1000-025
ABRA-
-D12-H12W-
-1000-032
ABRA-
-D12-H12W-
-1000-040
ABRA-
-D12-H12W-
-1000-050
L - installation length, mm  58 63 74 86 100 110
ød, mm  15  20 24,5 31,5 40 50
øD, mm   36 41 47 56  67 82
Кv, m3/h (Cv=1,17 Kv) 4 8 10,3 18 24 40
Weight, kg 0,160 0,212 0,310 0,460 0,700 1,035
Opening pressure MPa 0,03-0,05 = 3-5 wcm
Construction - check valve ABRA-D12 thredad ends:
N Description Qnt. Matherial
1 Корпус 1 Stainless steel Grade CF8M = W.-nr.1,4401 = DINX5CrNiMo17-12-2 = BS316S16 =EN 58J = AFNOR Z6CND17.11 = UNI X5CrNiMo1712 = UNE F.3543 = SS2347 = GB 0Cr17Ni11Mo2 = AISI/SAE 316 = JIS SUS 316 = GOST03Х17Н14М2
2 Уплотнение корпуса 1 PTFE
3

Диск

1 Stainless steel AISI/SAE SS 316
4 Пружина 1 Stainless steel AISI/SAE SS 316
5 Корпус 1 Stainless steel AISI/SAE SS 316

Construction - check valve ABRA-D12 thredad ends

Pressure / Temperature diagram for check valve ABRA-D12:

Pressure / Temperature diagram for check valve ABRA-D12

Diagram defines working pressure/tempetarure range for check valve ABRA-D12

Thread description for check valve ABRA-D12:

Name:

Ordinary european pipe thread:

Parallel pipe thread is used in parallel thread connections and also in connections of Female parallel thread to proper Male taper (conical) thread

The thread is based at BSW (British Standard Whitworth) and fit to BSP (British standard pipe thread) named BSPP.

Standards for reusable connections
  • ISO R228
  • EN 10226
  • DIN 259
  • BS 2779
  • JIS B 0202
  • GOST 6357-81
Abbreviation for appropriate Male reusable thread
  1. G, male, external - main abbreviation
  2. BSPP, male, external - often abbreviation
  3. BSP male, external - often, but not correct abbreviation (presumes BSPP, but you better check that it is not BSPT)
  4. PF, male, external - Japan JIS rare abbreviation
Abbreviation for appropriate Male nonreusable thread
  1. R, male, external - main abbreviation
  2. BSPT, male, external - often abbreviation
  3. PT, male, external - Japan JIS rare abbreviation

Installation and maintenance instruction for check valve ABRA-D12

  1. General.
    • All work must be carried out or be supervised by a suitably competent person. Installation and operating personnel should be trained in the correct use of the product according to the Installation and Maintenance Instructions. Where a formal 'permit to work' system is in force it must be complied with. Where there is no such system, it is recommended that a responsible person should know what work is going on and, where necessary, arrange to have an assistant whose primary responsibility is safety. Post 'warning notices' if necessary.
    • Before mounting you should check the valve for transportation or storage damage.  If you find that you should stop mounting until you get Seller's approval. 
  2. Mounting.
    • You should obligatory follow "General Installation and Commissioning demands"
    • Check valves are not deisgned and should not ever be used as shut-of valve. Lakage rate - rate АА accoding ISO 5208 nad GOST54808 and GOST 9544
    • Disc check valves are not suitable for use where heavily pulsating flow exists, such as close to a compressor.
    • Delete plastic plugs before mounting. Determine the correct installation situation and the direction of fluid flow.
    • Check materials, pressure and temperature and their maximum values. If the maximum operating limit of the product is lower than that of the system in which it is being fitted, ensure that a safety device is included in the system to prevent overpressurisation.
    • Before filling the pipeline, it is necessary to blow it out to remove scale and dirt.
    • The valve can be mounted on the vertical, inclined and horizontal pipelines. It is required to ensure sufficient space around the check valve for future service work if that will be ever necessary.
    • The flow should be directed according the arrow on the valve body.
    • After starting the system, make sure that there are no leaks in the assembly.
    • Don't forget to check for leakage after several hours of operation.
  3. Maintenance.
    • Check valves ABRA-D12 do not require constant maintenance. Parts are insoluble in aquatic media.
    • Periodically inspect the valve for fluid leaks.
    • Provision must be made to protect products which are not self-draining against frost damage in environments where they may be exposed to temperatures below freezing point.
    • Valve check out can be carried out when replacing pipelines.
      Attention!
    • Do not touch the working surfaces due to the fact that they could be very hot.
    • Before starting maintenance, make sure that the valve is not under pressure and does not have high temperature.
    • Do not remove the label with the marking from the valve.
    • Valves should be checked for leakages on the regular basis, espesially is they are not constanly in operation.
  4. Transportation and Storage.
    • Storage and transportation should be without shocks at temperature range: -60…+65 °С.
    • No parts or objects are allowed to be placed into check valve ABRA-D12
    • The valve should be kept in clean and weatherproof placements.
    • During transportation check valve ABRA-D12 should be properly protected from damage.
  5. Guarantee.
    • Guarantee is 12 month from installation but not more than 18 month from shipment if all demands of this manual are fulfilled.
    • Customers and stockists are reminded that under EC Health, Safety and Environment Law, when returning products to ABRA they must provide information on any hazards and the precautions to be taken due to contamination residues or mechanical damage which may present a health, safety or environmental risk. This information must be provided in writing including Health and Safety data sheets relating to any substances identified as hazardous or potentially hazardous.

Additional information from the Company ARADOX:

Please note! ABRADOX can accept no responsibility for possible errors in catalogues, brochures and other published materials. ABRADOX reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies and are not allowed to be used without the prior written permission of ABRADOX.

Design and IT support: KS  

DPVA.info Инженерный справочник.
E-mail: [email protected]
(+372) 5304 8184 / RU, EN, natuke ET - õpime
RU, EN, natuke ET - õpime

Contacts. Feedback.
© ABRADOX EUROPE OÜ 2019 - 2026
  DPVA.info Инженерный справочник.

HVAC, water supply and water treatment, industry and others